<LOGO>
FM Transmitter Measurement Report
Created: 2024-07-05 08-28-44
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
103.60 MHz 5/5, 50 dBuV COUNTRY
Pilot RDS Phase Difference
7.8 kHz 4.0 kHz 87 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 2,0 kHz
MIN Hold Max. Samples at Total Samples % above 77,0 kHz
12 kHz 37 kHz 18779 0,1917
Modulation Power
Limit Measuring Tolerance
0,0 dBr 0,2 dBr
MIN AVE MAX % above 0,2 dBr
-2,1 dBr -0,95 dBr 0,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"COUNTRY " 2337 25 (Country) 1 0 1 1 --:--
RT
"PETR SPALENY - HRAC "
AF EON
87.7, 89.5, 90.3, 91.6, 91.8, 91.9, 92.2, 92.7, 95.5, 95.6, 96.4, 96.8, 96.9, 101.8, 103.6, 103.7 MHz -
FM Scope Max at: 37 kHz MIN: 12 kHz % above 77 kHz: 0,1917 Acquired: 2024/07/05 8:28:41 Total samples: 18779 Equivalent time: 0:15:38 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 0,1 dBr MIN: -2,1 dBr AVE: -0,95 dBr % above 0,2 dBr: 0,0 Last value: -1,1 dBr (2024/07/05 8:28:41) 08:14 08:16 08:18 08:20 08:22 08:24 08:26 08:28 -4 -2 0 2 4 Pm [dBr] 0 5 Signal Quality